Can cells be fixed with 4% paraformaldehyde with the CYTO-ID® Autophagy detection kits (ENZ-51031 and ENZ-KIT175)?
A fixation step may be included when using the CYTO-ID® Autophagy detection kits (ENZ-51031 and ENZ-KIT175), but it needs to…
Tue, Jul 18, 2023
How does PATHO-GENE® HPV Type 11 Probe, ENZ-GEN151 work?
The ENZO PATHO-GENE® HPV Type 11 Probe (ENZ-GEN151) is a biotin-labeled DNA probe designed to hybridize to HPV Type 11 DNA sequences. The…
Tue, Jul 18, 2023
Is Autophagy Detection reagent in ENZ-51031 and ENZ-KIT175 compatible with anti-fluorescence quenching agent and fluoromount-G?
The CYTO-ID® Autophagy Detection reagent in ENZ-51031 and ENZ-KIT175 kits is compatible with anti-fluorescence quenching agent and Fluoromount-G.
Tue, Jul 18, 2023
Can the microplate be read following addition of ROS/Superoxide Detection Solution with ROS-ID® Total ROS/Superoxide detection kit, ENZ-51010?
Yes, plates can be read using bottom reading option without removing the ROS/Superoxide Detection Solution and without washing.
Tue, Jul 18, 2023
What is the difference is between Microycystin-LR (Analytical Standard), ALX-350-431 and Microcystin-LR, ALX-350-012?
Microycystin-LR (Analytical Standard), ALX-350-431-C010 and Microcystin-LR, ALX-350-012 differ in percentage purity. Microcystin-LR (Analytical Standard), ALX-350-431-C010 is =99% (HPLC). Microcystin-LR, ALX-350-012…
Tue, Jul 18, 2023
What are the Intra- assay and Inter-assay precision percent coefficient of variation for the concentrations between lots for E. coli host cell protein ELISA kit, ENZ-KIT127 ?
Concerning the E. coli host cell protein ELISA kit (ENZ-KIT127) our intra-assay %CV is
Tue, Jul 18, 2023
Is there a requirement for cell lysis with LEADING LIGHT® Wnt Reporter Assay, ENZ-61001
LEADING LIGHT® Wnt Reporter Assay (ENZ-61001) is a cell-based luciferase and does not require lysis and chemiluminescence signals can be…
Tue, Jul 18, 2023
How do we perform QC for E. coli host cell protein ELISA kit, ENZ-KIT127?
Quality control for E. coli host cell protein ELISA kit (ENZ-KIT127) is performed by randomly selecting multiple plates from each…
Tue, Jul 18, 2023
What could be the reason for low response to Wnt induction with LEADING LIGHT® Wnt Reporter Assay, ENZ-61001?
If observing a low response to Wnt induction with LEADING LIGHT® Wnt Reporter Assay (ENZ-61001), please consider the following. The…
Tue, Jul 18, 2023
Buffer salts in 10x PBS-T wash buffer in E. coli host cell protein ELISA kit, ENZ-KIT127 has precipitated upon storage at 4°C. Is this usual and how to dissolve the salts?
On occasions, buffer salts precipitate out of solution at 4°C. Warming the bottle containing buffer at 37°C and frequent vortexing would…
Tue, Jul 18, 2023
Lab Essentials
AMPIVIEW® RNA probes
Enabling Your Projects
GMP Services
Bulk Solutions
Research Travel Grant
Have You Published Using an Enzo Product?