Following staining with Mito-ID® Red detection kit, ENZ-51007, are the cells viable and is it possible to propagate cells?
The MITO-ID® Membrane potential dye (ENZ-51007) is not toxic to the cells at the concentrations and staining time recommended. Experiments demonstrated…
Tue, Jul 18, 2023

Can Mito-ID® Red detection kit (GFP-Certified®), ENZ-51007 and Mito-ID® Red antifade reagent, ENZ-53002 stain yeast cells ?
Staining of yeast cells with Mito-ID® Red detection kit has not been tested. The kit could work in yeast cells with optimization…
Tue, Jul 18, 2023

MSDS – Safety Data Sheets
All our SDSs are available for download directly from the product page.On the product page, please click the SDS link…
Tue, Jul 18, 2023

Is BIO-PROBE® 3’-Oligonucleotide labeling kit with bio-16-ddUTP, ENZ-42730-31 compatible with EMSA?
BIOPROBE® 3′-Oligonucleotide labeling kit with bio-16-ddUTP, ENZ-42730-31can be used for gel shift assays since the reaction yields uniformly labeled product.
Tue, Jul 18, 2023

What is the reason for the use of dye efflux inhibitor in the FLUOFORTE® Calcium assay kit (ENZ-51016, ENZ-51017, ENZ-51020)? Should this be used with all cell lines or is there an exception?
The use of the dye efflux inhibitor in the FLUOFORTE® Calcium assay kit (ENZ-51016, ENZ-51017, ENZ-51020) can help preventing the…
Tue, Jul 18, 2023

How long is the CYTO-ID® long-term cell tracer dye (ENZ-51036, ENZ-51037) retained in the cell and what cells were used to validate the assay?
The dye is well retained by cells for up to 96-120 hours after loading depending on how fast the cells…
Tue, Jul 18, 2023

Is the Red NUCLEAR-ID® dye in the NUCLEAR-ID® Blue/Red cell viability reagent provided with reference ENZ-53005 the same dye as NUCLEAR-ID Red for cell cycle analysis provided with reference ENZ-51008?
No, these are two different dyes.
Tue, Jul 18, 2023

Is it possible to combine FLUOFORTE® Calcium Assay Kit (ENZ-51016) with other fluorescence dye in a multiplex assay? What is the fluorescence excitation and emission of the dye?
It is possible to multiplex FLUOFORTE® Calcium Assay Kit with other assays as long as there is no spectral overlap…
Tue, Jul 18, 2023

Can you provide an overview of cell proliferation experiments with the CYTO-ID® long-term cell tracer kits (ENZ-51036, ENZ-51037)?
It is possible to kinetically monitor the ability of the cells to proliferate with CYTO-ID® Red long-term cell tracer kit…
Tue, Jul 18, 2023

What is the recommended exposure setting for NUCLEAR-ID® red stain (ENZ-52406)?
The exposure depends on the microscope and filters. With a 50% neutral density filter, 1 second exposure is a good starting point.