What is the recommended solvent to dissolve Microcystin-LR, ALX-350-012 and what is the maximum solubility?
Maximum solubility of Microcystin-LR (ALX-350-012) is 10 mg/ml in 100 % ethanol, methanol or DMSO.
Tue, Jul 18, 2023
What buffer should be used to dilute standards, ATP and active PKC in ADI-EKS-420A, PKC Kinase Activity Assay Kit?
Only Kinase Assay Dilution Buffer (80-1486) provided with PKC kinase activity kit (ADI-EKS-420A) should be used to dilute ATP, Standards…
Tue, Jul 18, 2023
How critical is four minutes centrifugation at 13,800 x g following boiling and cooling samples at step 5 in sample handling with Protein A ELISA kit, ADI-900-057?
The recommended centrifugation is 4 min at 13,800 x g. Depending on your centrifuge, you may need to adjust time…
Tue, Jul 18, 2023
Does PACOCF3, BML-ST336 inhibit all isoforms of phospholipase A2 (PLA2)?
PACOCF3 (BML-ST336) inhibits of both Ca2+-dependent cytosolic cPLA2 (IC50=45 µM) and Ca2+-independent phospholipases A2 iPLA2 (IC50=3.8 µM). Unfortunately, we have…
Tue, Jul 18, 2023
What are the Intra- assay and Inter-assay precision percent coefficient of variation for the concentrations between lots for E. coli host cell protein ELISA kit, ENZ-KIT127 ?
Concerning the E. coli host cell protein ELISA kit (ENZ-KIT127) our intra-assay %CV is
Tue, Jul 18, 2023
What could be the reason for low response to Wnt induction with LEADING LIGHT® Wnt Reporter Assay, ENZ-61001?
If observing a low response to Wnt induction with LEADING LIGHT® Wnt Reporter Assay (ENZ-61001), please consider the following. The…
Tue, Jul 18, 2023
Can the microplate be read following addition of ROS/Superoxide Detection Solution with ROS-ID® Total ROS/Superoxide detection kit, ENZ-51010?
Yes, plates can be read using bottom reading option without removing the ROS/Superoxide Detection Solution and without washing.
Tue, Jul 18, 2023
How do we perform QC for E. coli host cell protein ELISA kit, ENZ-KIT127?
Quality control for E. coli host cell protein ELISA kit (ENZ-KIT127) is performed by randomly selecting multiple plates from each…
Tue, Jul 18, 2023
Buffer salts in 10x PBS-T wash buffer in E. coli host cell protein ELISA kit, ENZ-KIT127 has precipitated upon storage at 4°C. Is this usual and how to dissolve the salts?
On occasions, buffer salts precipitate out of solution at 4°C. Warming the bottle containing buffer at 37°C and frequent vortexing would…
Tue, Jul 18, 2023
How does PATHO-GENE® HPV Type 11 Probe, ENZ-GEN151 work?
The ENZO PATHO-GENE® HPV Type 11 Probe (ENZ-GEN151) is a biotin-labeled DNA probe designed to hybridize to HPV Type 11 DNA sequences. The…
Tue, Jul 18, 2023