
Can the Cortisol ELISA kit be used with samples from any species?
Cortisol is conserved across all species and the antibody provided in the kit will bind to cortisol independently from the…
Tue, Jul 18, 2023

Would membrane proteins work with ProteoStat® Thermal Shift Stability Assay Kit, ENZ-51027, and ProteoStat® Detection Reagent in ProteoStat® Protein Aggregation Assay, ENZ-51023?
We have not tested the ProteoStat® Protein Aggregation Assay, ENZ-51023, or ProteoStat® Thermal Shift Stability Assay Kit, ENZ-51027, with membrane…
Tue, Jul 18, 2023

What are the main advantages of working with ProteoStat® Thermal Shift Stability Assay Kit, ENZ-51027?
The ProteoStat® Thermal Shift Stability Assay kit works over a wide temperature, pH and ionic strength range and is compatible…
Tue, Jul 18, 2023

What does ProteoStat® dye bind to and what is the mechanism of detection of protein aggregation?
The molecular rotor dye is non-fluorescent due to free rotation around a central carbon-carbon single bond separating different aromatic portions of…
Tue, Jul 18, 2023

Two peaks with ProteoStat® Thermal Shift Stability Assay kit, ENZ-51027, were observed. What is the explanation?
One possible explanation for the two peaks is the presence of two proteins in the sample. If the test protein contains…
Tue, Jul 18, 2023

If the test protein is a variant with near identical amino acid sequence with the exception of one residue, is one peak expected ?
There may be a possibility of different conformations of the same protein aggregating at different temperatures. The sample could have…
Tue, Jul 18, 2023

What thermal cyclers have the protocol been tested with ProteoStat® Thermal shift stability assay kit, ENZ-51027?
ProteoStat® Thermal shift stability assay should work on all types of thermal cyclers in the market. It has been tested…
Tue, Jul 18, 2023

What detergents are compatible with ProteoStat® Thermal Shift Stability Assay kit, ENZ-51027 and ProteoStat® Protein Aggregation Assay?
The ProteoStat® dye is compatible with some detergents, such as 0.1% Tween 20, but this varies with the protein used. …
Tue, Jul 18, 2023

How does the steroid displacement reagent (SDR) work?
Steroids in circulation are almost all ionically bound to carrier proteins such as albumin or more specific binding proteins. Treating…
Tue, Jul 18, 2023

Why is there sample dilution necessary in this ELISA Kit?
There are several reasons for dilutions. In some cases samples might read above the standard curve, thus requiring a dilution…
Tue, Jul 18, 2023