Where do I find validation data for Protein A ELISA kit, ADI-900-057 since this is not listed on datasheet?
Description of Validation experiments and the data for Protein A ELISA kit (ADI-900-057) are listed in pages from 9-11 of…
Tue, Jul 18, 2023

How is the Protein A ELISA kit, ADI-900-057 validated?
The Protein A ELISA Kit (ADI-900-057) recognizes natural and recombinant forms of Protein A. Four Protein A constructs were evaluated…
Tue, Jul 18, 2023

What information does Lot specific Certificate of Analysis for Protein A ELIA kit, ADI-900-057 have?
Lot specific Certificate of Analysis for Protein A ELISA kit (ADI-900-057) lists: assay range, OD values for High, Medium, Low,…
Tue, Jul 18, 2023

Can Sample diluent (80-1504) be used to dilute antibody if one runs out of antibody diluent (80-1759) with HO-1 (human), ELISA kit, ADI-EKS-800?
We do not recommend using Sample diluent (80-1504) to dilute antibody instead of antibody diluent (80-1759) with HO-1 (human), ELISA…
Tue, Jul 18, 2023

How does MITO-ID® dye in the Membrane Potential kits, ENZ-51018 and ENZ-51019 detect membrane potential?
MITO-ID® Membrane Potential Kits (ENZ-51018, ENZ-51019) measures mitochondrial membrane potential with a cationic dye dual-emission dye that exists as green…
Tue, Jul 18, 2023

What advantages does MITO-ID® Membrane Potential Kits, ENZ-51018 and ENZ-51019 offer compared to JC-1 and JC-10?
Compared with the commonly used cationic carbocyanine dye JC-1 and JC-10, the MITO-ID® membrane potential dye (ENZ-51018 and ENZ-51019) offers…
Tue, Jul 18, 2023

What is the suggested volume of SEEBRIGHT® Red 598 dUTP, ENZ-42855 and SEEBRIGHT® Green 496 dUTP, ENZ-42831 with Nick translation DNA labeling system 2.0, ENZ-GEN111-0050?
We suggest to reconstitute the dyes (0.3 mM) and use the same volumes as mentioned in the manual of the…
Tue, Jul 18, 2023

How many filters does the Absorbance 96 plate reader come with?
The Absorbance 96 plate reader comes equipped with four (4) filters with wavelengths of your choice.
Tue, Jul 18, 2023

Can the Absorbance 96 plate reader be equipped with UV filters?
Unfortunately not. The shortest available wavelength filter is 400 nm. But many wavelengths between 400-990 nm are available.
Tue, Jul 18, 2023

What is the recommendation to reconstitute the SEEBRIGHT® lyophilized dUTPs, ENZ-42853L, ENZ-42843L, ENZ-42831L, ENZ-42842L?
Dissolving in 10 mM TE pH8, is the preferred method since the nucleotides are stable for long term -20°C storage.…
Tue, Jul 18, 2023