Where to locate the lot number of my product?
Lot numbers are indicated on all our product labels. You will need to locate your product’s lot number in order…
Wed, Jul 19, 2023
Why is boiling samples necessary with Protein A ELISA kit, ADI-900-057?
Samples containing IgG requires boiling to dissociate Protein A in the sample from IgG
Tue, Jul 18, 2023
Does Cellular senescence activity assay, ENZ-KIT129 require running standards and are standards provided with this kit?
Cellular senescence activity assay, ENZ-KIT129 is designed as semi quantitative assay. Therefore, standards are not provided. As shown on page 7…
Tue, Jul 18, 2023
For Quantitation Limit (QL) with E. coli Host Cell Protein ELISA kit, ENZ-KIT127, why is 10 ng/mL chosen for precision and accuracy?
A measurable slope is observed between 10 and 30 ng/mL concentrations and anything below 10 ng/mL cannot be easily validated.
Tue, Jul 18, 2023
What is the percent error range set for newly manufactured lots of E. coli Host Cell Protein ELISA kit, ENZ-KIT127?
We do not have defined cut-offs for % error when looking at the performance of new plate lots. Quality control…
Tue, Jul 18, 2023
What is the recommended sample volume to use for the TFA extraction protocol with Substance P ELISA kit, ADI-900-018A ?
Frequently used sample volumes for Substance P ELISA kit range from 250 µl – 5ml. Depending on the type of…
Tue, Jul 18, 2023
Would the results obtained with Creatinine colorimetric detection kit, ADI-907-030 and Creatinine colorimetric detection kit, ADI-907-030A be identical?
Results obtained with old and new version kit would not be identical. But, the values would be close and comparable…
Tue, Jul 18, 2023
What is the correct MW of Doxycycline . hyclate, ALX-380-273?
Molecular weight of Doxycycline. hyclate is based on the empirical formula. C46H58Cl2N4O18, , dimeric form has a MW of 1025.87 and…
Tue, Jul 18, 2023
Are results from Creatinine colorimetric detection kit, ADI-907-030A and Creatinine colorimetric detection kit, ADI-907-030 comparable?
Data obtained from Creatinine colorimetric detection kit, ADI-907-030A and Creatinine colorimetric detection kit, ADI-907-030 are comparable for the same set…
Tue, Jul 18, 2023
What is the purity, volume and amounts of Bio-17-ATP, ENZ-42817 provided?
Biotin-17-adenosine-5′-triphosphate is =93% (HPLC), the amount is 250 nmol in a volume of 25 ul.