Can the ProteoStat® TS Detection Reagent in the thermal shift stability assay kit, ENZ-51027, be substituted with the detection reagent from the ProteoStat® Protein Aggregation Assay, ENZ-51023?
Theoretically, the two dye reagents can be interchanged but this would require some optimization.
Tue, Jul 18, 2023

Would the aggregation temperature as determined using ProteoStat® Thermal Shift Stability Assay kit, ENZ-51027, be the same as determined using the Thermofluor technique?
In Thermofluor technique, SYPRO Orange, an environment-sensitive dye, is used to measure the unfolding of the protein as the temperature…
Tue, Jul 18, 2023

What are the critical points to pay attention to during preparation of ß-Lactoglobulin solution?
During preparation of ß-Lactoglobulin solution, the following points should be noted: The ß-Lactoglobulin Control is supplied as a lyophilized powder…
Tue, Jul 18, 2023

Is the binding of the protein to the ProteoStat® detection dye reversible?
The interaction between the ProteoStat® dye and the protein aggregates is non-covalent. So, in theory it is a reversible interaction.…
Tue, Jul 18, 2023

Is it possible to distinguish between protein aggregates of different sizes using ProteoStat® Protein Aggregation Assay, ENZ-51023?
The ProteoStat® detection dye does not differentiate aggregate sizes. The dye will bind to a wide range of protein aggregate…
Tue, Jul 18, 2023

Can Cyto-ID® Green autophagy detection reagent from Cyto-ID® Autophagy detection kit, ENZ-51031, be used in combination with ProteoStat® Detection Reagent in ProteoStat® Protein aggregation assay, ENZ-51023?
Since there is no spectral overlap between Cyto-ID® Green Autophagy Detection Reagent and ProteoStat® Detection Reagent, they can be used…
Tue, Jul 18, 2023

How different is ProteoStat® TS Detection Reagent in ENZ-51027 from ProteoStat® Detection Reagent in ENZ-51023?
ProteoStat®TS Detection Reagent in ProteoStat® Thermal Shift Stability Assay Kit, ENZ-51027, and ProteoStat®Detection Reagentin ProteoStat® Protein Aggregation Assay, ENZ-51023, are…
Tue, Jul 18, 2023

Can DNA labeled with the Enzo Life Sciences kit be used on a Roche NimbleGen™ platform?
Yes, it can be used. It has been noted by cytogenetics labs that Enzo’s CGH labeling kit works perfectly well…
Tue, Jul 18, 2023

Immunoassay Good Lab Practices
Always read and follow the product instructions. The information contained in the kit manual is your first source of knowledge…
Tue, Jul 18, 2023

Units Conversion Table
Molecule Formula Weight Units Conversion Factor Other Units 2,3-dinor-6-keto-Prostaglandin F1a 342.5 pg/ml 2.92 pmol/l 6-keto-Prostaglandin F1a 370.5 pg/ml 2.7 pmol/l…