Does the Hypoxia Red Detection Reagent provided with ROS-ID® Hypoxia/Oxidative stress detection kit, ENZ-51042, retain the red stain during oxygenation?
The hypoxia dye in the ROS-ID® Hypoxia/Oxidative stress detection kit, ENZ-51042, does not fade during oxygenation.
Tue, Jul 18, 2023

How long does the fluorescence last post-staining with the ROS-ID® Hypoxia/Oxidative stress detection kit, ENZ-51042?
Storing the samples stained with the ROS-ID® Hypoxia/Oxidative stress detection kit, ENZ-51042, protected from exposure to direct light would help…
Tue, Jul 18, 2023

Is the peptide substrate coated on the microtiter plate present in the ADI-EKS-390A kit specific for PKA?
No, the peptide substrate in the PKA kinase activity kit (ADI-EKS-390A) is not specific to PKA and therefore it can…
Tue, Jul 18, 2023

What exactly does the kit ADI-EKS-895 detect?
The kit ADI-EKS-895 is specific for human Hsp90a and will not react with human Hsp90ß. Human Hsp90a and Hsp90ß are…
Tue, Jul 18, 2023

What is the half-life of Hypoxia Red Detection Reagent and Oxidative Stress Detection Reagent in the ROS-ID® Hypoxia/Oxidative stress detection kit, ENZ-51042?
We have not determined the half-life of the dyes provided with the ROS-ID® Hypoxia/Oxidative stress detection kit (ENZ-51042) but both…
Tue, Jul 18, 2023

Do you sell a positive control for ADI-900-175, Serotonin ELISA kit, or could you advice on a suitable one?
We do not provide positive control samples with the kit. If you need to ensure accurate recovery of Serotonin from…
Tue, Jul 18, 2023

Can I use the kit ADI-EKS-895 to measure HSP90a activity?
ADI-EKS-895 is used to measure the total amount of human HSP90a in a given sample. It cannot be used for…
Tue, Jul 18, 2023

How were the <i>E.coli</i> host cell protein standards generated?
Most of the E.coli strains used in the industry and in the production of biologics are derived from K12. The…
Tue, Jul 18, 2023

The sensitivity of ADI-900-020A is listed as 0.41 pg/mL, whereas the standard range only goes as low as 0.78 pg/mL. What is the limit of detection of the assay?
Limit of detection is a statistical measurement meant to indicate the lowest concentration that the assay can differentiate from zero…
Tue, Jul 18, 2023

How long may plasma samples be stored (with EDTA and aprotinin or with EDTA-only)? Has this been tested? Is there some degradation of Endothelin-1 while samples are stored?
Plasma samples collected as directed with EDTA and Aprotinin will be stable for at least 1 month at -80°C without…
Tue, Jul 18, 2023